Rotary Diesel UPS Also see Description of Operation + References


The Hitzinger Dynamic Rotary Diesel UPS, uninterruptable power supplies, system comprises of four major components: diesel engine, generator, kinetic energy storage module and coupling choke. The kinetic energy module, generator and coupling choke work together to provide power conditioning and ride through energy for the UPS system, whilst the diesel engine provides the long-term back up for a mains failure. These systems provide extremely high availability and reliability in case of mains failure and high efficiency during stand-by operation because of carefully design and individual components selection. Mains failure of as a little as a millisecond will cause serious consequences and expensive production outage and subsequent mistake costs in a wide range of industrial, electronical, airports, computer  centres  and  healthcare  applications.

300KVA Rotary Diesel NBDK DRUPS

 

Maximum availability and reliability

 

The reliability of Hitzinger Rotary Diesel UPS systems is the result of product philosophy with the use of a minimum number of system components having an optimum quality standard.

 

Coupling Choke

 

Within a Diesel UPS system the coupling choke connects the input grid supply with the UPS high quality output supply. It allows large voltage differences between both AC systems by means of reactive currents for any direction, independent of the active power flow. The special design of the choke provides a high degree of de-coupling in both directions between the input and the output. The Coupling choke provides: Static and transient voltage decoupling of the input mains and the UPS bus -Harmonic filtering -Input load levelling irrespective of 100 % unbalanced output load -Input Power factor correction > 0.98 from 0 - 100 % load at nominal voltage. In the event of input short circuit the current flow towards the grid network is limited by the choke to < 200 % I nominal until the input is disconnected. During this transient the current feed back to the mains is wholly reactive, ensuring all the kinetic stored energy can be fully utilised for the critical load.
 

Hitzinger Diagnostic and Monitoring System

 

Hitzinger offers complete information software package for monitoring and control of the power supply systems through serial interfaces over a network, intranet or remote connectivity via modem links etc.

 

Typical Schematic Diagram

 

 

     1 Diesel engine                                        9 Consumer power switch
     3 Electromagnetic clutch                          10 Alternator guards                            
     4 Kinetic module                                      11 By-Pass- Power switch
     6 Synchronous alternator                          12 Grid supply
     7 Choke                                                  13 User output of UPS
     8 Grid power switch                                  15 Voltage peaks
     14 Harmonic distortion                              16 Voltage cut-offs
     17 Interruptions

 

Specification

  • Rating: up to 2500 kVA Voltage: up to 11 kV direct Dual output units

  • MTBF value: >1M hours

  • Availability: >99.9999 %

  • Low MTTR value

  • Low maintenance costs

  • Battery less solution

  • High overload capacity

  • Efficiency up to 96 %

  • Electromagnetic clutch

  • Power factor improvement

  • Brushless design, no slip rings

  • Reduced plant room footprint

  • Maximum availability and reliability

 

For more information on the Rotary Diesel UPS systems you can Contact Us or Request a Brochure